RE: [Histonet] CD31 staining histiocytes???

From:"Patsy Ruegg"

You may be over heating your samples for cd31, I had to go to a waterbath at
80dc for 3 hours using the low ph hier buffer.

Patsy Ruegg, HT(ASCP)QIHC
IHCtech, LLC
Fitzsimmons BioScience Park
12635 Montview Blvd. Suite 216
Aurora, CO 80010
wk email
web site

This email is confidential and intended solely for the use of the Person(s)
('the intended recipient') to whom it was addressed. Any views or opinions
presented are solely those of the author. It may contain information that is
privileged & confidential within the meaning of applicable law. Accordingly
any dissemination, distribution, copying, or other use of this message, or
any of its contents, by any person other than the intended recipient may
constitute a breach of civil or criminal law and is strictly prohibited. If
you are NOT the intended recipient please contact the sender and dispose of
this e-mail as soon as possible.

-----Original Message-----
[] On Behalf Of Histology
Sent: Thursday, November 17, 2005 7:10 AM
Subject: [Histonet] CD31 staining histiocytes???

Hello all:
  Is anyone out there using Dako CD31 and getting histiocyte staining in
human skin???  Our dermpath is seeing this and is questioning it.  We are
using it at 1:100 with the biocare pressure cooker with Biocare Diva
decloaker solution.  Our detection system is Envision +.  Any thoughts???
  Histopathology Supervisor
  St. Louis University Medical School