Re: [Histonet] Disect-Aid

From:Rene J Buesa

Hi Sylinda:
We used for lymph nodes the following solution:
100% ethanol ------2 L + Distilled water -----0.68 L + 37% formaldehyde ---0.32 L + acetic acid--0.2 L (for a total of 3.20 L).
It worked very well and even the smallests lymph nodes could be detected.
Rene J.

BSylinda@aol.com wrote:
Hi Histoland,
I am writing for more information about disect-aid. Do anyone have any 
experience in using this reagent for fatty tissue such as lymph node tissue. 
Out pathologist is interested in trying this. Any feedback of pros and 
cons of using this product would be greatly appreciated. Could you also forward 
vendor information as well.

Thanks,
Sylinda

_______________________________________________
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet



		
---------------------------------
 Yahoo! FareChase - Search multiple travel sites in one click.  
_______________________________________________
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet


<< Previous Message | Next Message >>