[Histonet] LMD ... IHC sections falling off

From:Amos Brooks

Victoria,
         Firstly try thinner sections 10 um is a bit thick. Next you should 
use some type of charged, silanized or APES slides. You can either silanize 
your own slides or buy them from a vendor. Adhesives aren't necessarily 
good for IHC as they can interfere with the reaction.
Amos Brooks



>Message: 5
>From: victoria.hahn-stromberg@orebroll.se
>To: histonet@lists.utsouthwestern.edu
>Date: Mon, 20 Oct 2003 13:20:39 +0200
>Subject: [Histonet] LMD
>
>Hi!
>I=B4m having problems with my LMD slides.  I use 10um paraffin embedded
>histological sections which I would like to stain immunohistochemically =
>with
>CAM, but the sections keep falling off, can anyone plesse help =
>me??/Victoria
>
>Victoria Hahn-Str=F6mberg
>MSc, PhD student
>Kliniken f=F6r Patologi
>Universitetssjukhuset =D6rebro
>701 85 =D6rebro
>tel:  019-6023644
>faxnr:019-6021035


_______________________________________________
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet


<< Previous Message | Next Message >>