RE: [Histonet] c4d

From:"Sebree Linda A."

Hi Gudrun,

For frozen sections we use Biogenesis C4d at 1:600 on our Benchmark XT for 24" with AB block.  We pretreat our acetone fixed sections in VMS Morphosave for 2" but this isn't a critical step and frozens will stain without it.  For paraffin sections, we perform HIER in EDTA in a Biocare decloaking chamber for 3" followed by a 32" incubation and VMS amplification as well as AB block.  We use rejecting kidney as a control as our patient specimens are 95% renal biopsies being tested for possible rejection.

Hope this is of some help,

Linda A. Sebree
University of Wisconsin Hospital & Clinics
IHC/ISH Clinical & Research Laboratory
600 Highland Ave.
Madison, WI 53792
FAX:  (608)262-7174

-----Original Message-----
From: [] On Behalf Of Gudrun Lang
Sent: Tuesday, November 29, 2005 9:18 AM
To: Histonetliste (Histonetliste)
Subject: AW: [Histonet] c4d

Dear Richard,
We are going to introduce this antibody in our lab. We work with the Benchmark XT. Can you give me some hints about the titer and incubation time you use? Or what tissue is preferd as a positiv control? Does it work constantly?

Thank you
Gudrun Lang
Histotech, Akh Linz

-----Ursprüngliche Nachricht-----
[] Im Auftrag von Richard Cartun
Gesendet: Freitag, 25. November 2005 20:15
Betreff: Re: [Histonet] c4d

We use a rabbit polyclonal antibody from American Research Products, Inc. located in Belmont, MA.  The catalog number is 12-5000.


Richard W. Cartun, Ph.D.
Director, Immunopathology & Histology
Assistant Director, Anatomic Pathology
Hartford Hospital
80 Seymour Street
Hartford, CT  06102
(860) 545-1596
(860) 545-0174 Fax

>>>  11/02/05 02:30PM >>>
Could anyone recommend a monoclonal C4d antibody for FFPE human tissue?


CONFIDENTIALITY NOTICE: This e-mail and any files/attachments may contain confidential, personal and/or privileged information intended for a specific purpose and recipient. If you are not the intended recipient do not disclose, copy, retain, distribute, use or modify any of the contents of this transmission. If you received this transmission in error please notify the sender immediately by return e-mail or telephone and destroy the entire transmission and any copies produced. Thank you.

Histonet mailing list

Confidentiality Notice

This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential or proprietary information which is legally privileged.  Any unauthorized review, use, disclosure, or distribution is prohibited.  If you are not the intended recipient, please promptly contact the sender by reply e-mail and destroy all copies of the original message.