RE: Stereology on thick sections/technovit 7200
From: | rita.russell@syngenta.com |
Sorry!!!Yes you're right it is 7100(GMA) we used.
> ----------
> From: Linda Durbin[SMTP:Linda.Durbin@ExaktUSA.com]
> Sent: 12 July 2001 01:20
> To: Russell Rita GBAP
> Subject: RE: Stereology on thick sections/technovit 7200
>
> Rita:
>
> Are you really using Technovit 7200 or is it 7100 (GMA). Or maybe
> 9100(MMA). 7200 is very brittle. If it is 7200 I'd love to know how
> you're
> softening it.
>
> Thanks in advance.
>
> Linda Durbin
>
>
> -----Original Message-----
> From: rita.russell@syngenta.com
> To: histonet@pathology.swmed.edu
> Sent: 7/11/01 2:15 AM
> Subject: Stereology on thick sections/technovit 7200
>
> We cut sections of whole rat brains at 30 microns embedded in tecnovit
> 7200
> using a solid tungsten carbide knife. Keep the edge of the knife moist
> but
> not too wet with distilled water, and cut very slowly. Float out on
> distilled wa