RE: [Histonet] AE1/AE3 cross reactivity

From:Mighnon Lashus



We do not use AR for the AE1/AE3 on our Ventana system.  We use Protease 1 for 4 minutes.  I will check into the heat.  Any other suggestions?  We do the stains for Dr. Hessler.
Thanks,
Mighnon Lashus

-----Original Message-----
From: histonet-bounces@lists.utsouthwestern.edu [mailto:histonet-bounces@lists.utsouthwestern.edu] On Behalf Of Sally Price
Sent: Wednesday, January 16, 2008 5:53 PM
To: Richard Hessler, M.D.; histonet@lists.utsouthwestern.edu
Subject: RE: [Histonet] AE1/AE3 cross reactivity

Dr. Hessler:
I have observed the phenomenon that you've described for other antibodies
more times than I can remember.  Personally, I believe that it has to do
with the way the Ventana system sprays on the retrieval solution
and heats slides during antibody/detection incubation periods, which is too
aggressive.  I think that an open system that doesn't heat slides or perform
AR isn't likely to produce these unexpalined reactions, but I digress.  So,
how do you fix the problem?  I say disable the on-line AR, and perform it in
a decloaking chamber, set at 100 degrees for 10 minutes.  Or, you could
consider using another pan-CK antibody, like Lu-5.
Good Luck,
Sally Price

----------------------------------------------------------------------------------------------

Date: Wed, 16 Jan 2008 07:57:41 -0600
From: "Richard Hessler, M.D." 
Subject: [Histonet] AE1/AE3 cross reactivity
To: "histonet@lists.utsouthwestern.edu"
    
"
I have used this antibody for years but now have issues. Previously it was
the best choice for breast sentinel nodes, but now AE1/AE3  stains plasma
cells like CD138. It also stains a number of different sarcomas and
beautifully highlights reactive astrocytes. I had previously used Dako Ab
and autostainer with no problems. Now I have Ventanna and have noticed this
with both Ventana and Dako Abs used on that system.

Any thoughts???

Richard B Hessler, MD
Chief of Pathology
Erlanger Medical Center
Chattanooga, TN
_______________________________________________
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet

Important Notice:  This e-mail is intended for the use of the person to whom it is addressed and may contain information that is privileged and confidential.  If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this message is strictly prohibited.  If you have received this e-mail in error, please destroy this message and contact the Security Officer at PathGroup, Inc immediately at 615-562-9255.  Thank you

_______________________________________________
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet




<< Previous Message | Next Message >>