Dear Jim
V-line calretinin from Zymed works very well on the ventana systems, fresh 
lung control (oxidation sensitive) harsh microwave retrieval (citrate) 32 min 
incubation.
Retrieval method--- 800 watt microwave
                            4 plastic coplin jars
                           60ml buffer in each or water in those with no 
slides
                              5min 30 seconds on high
                                 11min 30 sec on 30% power
                                cool 10 min-stain
will stain mesothelial cells in normal lung.              Dana